- Light tack cure option for quick and easy removal of excess cement
- High bond strength
- No Bisphenol A or derivatives
- Greater stain resistance
- Sustained fluoride release
SDI Rivacem is a resin modified glass ionomer luting material. It has self-curing, radiopaque, fluoride releasing properties.
- 1 x 8.5gms syringe
riva cem is a self-curing, radiopaque, fluoride releasing paste/
paste resin modified glass-ionomer luting material. It is indicated for permanent cementation of metal-based and strengthen-core ceramic restorations, and orthodontic appliances
riva cem comes with the additional light tack cure option for early removal of excess cement, excellent tooth adhesion, fluoride release and ideal flowability, for your cementation needs. riva cem is available in a universal light yellow shade in double barrel syringe which can easily be hand mixed.
INDICATIONS FOR USE:
|
Indicated material |
Type of restorations |
|
PFM |
Crowns & Bridges |
|
Resin |
Crown, bridges, inlays, onlays & posts (fiber-reinforced) |
|
Metals |
Crown, bridges, inlays & onlays, orthodontic appliances & posts |
|
Ceramics (high strength) |
Crowns & Bridges |
|
All-ceramic |
Inlays |
CONTRA-INDICATIONS:
- Pulp capping
- Product may cause skin irritations to some people. In such cases, discontinue use and seek medical attention. Any persons having known resin allergies should immediately discontinue use.
INSTRUCTIONS FOR USE:
- PREPARATION:
- Prepare tooth using standard clinical guidelines.
- For optimum adhesion, condition the tooth with riva conditioner (SDI Ltd.) for 10 seconds. Rinse thoroughly with water and remove excess water.
- In cases where pulp protection is necessary, use a calcium hydroxide liner or a resin-modified glass-ionomer liner such as riva bond LC P/L (SDI Ltd.)
- MIXING PROCEDURE:
|
Paste / Paste ratio (g/g) |
2.0/1.0 |
|
Mixing time (min, sec.) |
0’15" |
|
Working time (min, sec.)1,2 (from start of mixing) |
1'45" |
|
Excess cement: - Tack light cure |
5 second per surface For tack light curing, use a high power conventional polymerization device (460-480 nm) |
|
Excess cement: - Self-curing gel-phase2 |
1’45” after seating the restoration |
|
Setting time (min, sec.)2 (after seating the restoration) |
4'30" |
|
Radiopacity |
1.5 mm Al |
1 Test conditions: temperature (23 ± 1°C, 73± 1°F), relative humidity (50 ± 10%). ISO 9917-2
2 These times are approximate only, and may vary based on storage conditions, humidity, age of product and temperature.
- Remove the syringe from the foil pack.
- Remove the cap from the syringe.
- Before each use, dispense a small amount to ensure even dispensing or to remove any dried out paste. Discard this material.
- Extrude required amount of pastes onto a mixing pad.
Important: Ensure the thumb is positioned firmly in the middle of the plunger to obtain the correct dispensing ratio of the two pastes.
- Using a spatula, mix the two pastes together thoroughly for 15 seconds. Be careful not to incorporate air bubbles.
Note: Do not expose riva cem paste directly to operatory light to avoid early setting of the material.
- CEMENTATION PROCEDURE:
- Ensure the internal surface of the restoration to be seated is cleaned, dried and prepared according to manufacturer’s instructions.
- Apply a thin layer of cement to the bonding surface.
- Seat the restoration within 30 seconds of completion of mixing before any light curing is carried out.
Note:
-
- Avoid overfilling crowns.
- Room temperatures above 23°C/73°F will reduce the working time.
- Light cure any excess material for 5 seconds per surface using a high power LED curing light (460-480nm emission).
- Gently remove excess material using a scaler or explorer.
Note: Excess can also be removed during self-curing gel stage (when cement feels rubbery), after 1 min 45 seconds.
- Maintain isolation for at least 4 min 30 seconds after seating of restoration.
STORAGE AND HANDLING:
- Avoid excess heat and direct sunlight.
- Do not remove riva cem syringes from foil packets until ready to use.
- Store between 10°C and 25°C (50° - 77°F).
- If stored at cooler temperature allow product to reach room temperature prior to use.
- Use at room temperature between 20°C and 25°C (68° - 77°F)
- Store with cap securely attached to the syringe. Do not allow the pastes to dry out.
PRECAUTIONS:
- For professional use only.
- Do not take internally.
- Do not use after expiry date.
- Caution: Federal Law restricts this device to sale by or on the order of a dentist.
- SDS available at www.sdi.com.au or contact your regional representative.
FIRST AID:
- Eye (contact): Wash thoroughly with water and seek medical attention.
- Skin (contact): Remove using a cloth or sponge soaked in alcohol. Wash thoroughly with water.
- Ingestion: Drink plenty of water/milk. Seek medical attention if symptoms persist.
- Inhalation: No symptoms expected.
Related Products
Latest Blogs
Coltene, over the years since its establishment, has emerged as one of the leading manufac...
Read MoreGood oral health plays an important role in our lives. It has several life-changing advant...
Read MoreGood oral health and hygiene have plentiful benefits. It not just earns you an attractive...
Read MoreDental braces are dental devices that orthodontists use to reposition and straighten your...
Read MoreDental bonding also known as teeth bonding is a cosmetic procedure done to repair chips, c...
Read MoreWith the growth of the dental industry, it is essential to try and find out which are the...
Read MoreWhen it comes to delivering high-quality dental care, the Coltene Rubber Dam Kit stands ou...
Read MoreIn restorative dentistry, composite materials play a vital role in delivering functional a...
Read MoreAs a trusted supplier, ID Enterprises offers top-quality NeoEndo rotary files designed to...
Read More